SE 3102 C33
ICA UPS SE 3102 C33 Capacity 30.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.
Model | : | UPS SE3102C33 |
Capacity INPUT |
: | 30000 VA / 27000 W |
Nominal Voltage | : | 380 / 400 / 415 Vac (3Ph+N+PE) |
Operating Voltage Range | : | 208 ~ 478 Vac |
Operating Frequency Range | : | 45~55Hz / 54~66Hz (auto sensing) |
Power Factor | : | ≥0.99 |
Bypass Voltage Range | : | 380Vac Max. voltage: 25% (optional +10%, +15%, +20%) 400Vac Max. voltage: +20% (optional +10%, +15%) 415Vac Max. voltage: +15% (optional +10%) Min. voltage: -45% (optional -20%, -30%) |
Bypass Frequemcy Range | : | Frequency synchronize tracing range: ±10% | ECO Range | : | Same as bypass |
Harmonic Distortion (THD) | : | ≤3% (100% non-linear load) |
BATTERY | Battery Voltage | : | ±120Vdc |
Backup Time | : | 10 minutes at nominal load | Backup Configuration | : | External |
OUTPUT | Output Voltage | : | 380 / 400 / 415 Vac (3Ph+N+PE) |
Power Factor | : | 0.9 | Voltage Regulation | : | ±1% |
Frequency Line Mode | : | ±1%/ ±2%/ ±4%/ ±5%/ ±10% of the rated frequency (optional) | Frequency Bat. Mode | : | 50/60 (±0.1)Hz |
Crest Factor | : | 3:1 | Harmonic Distortion (THD) | : | ≤2% with linear load ≤5% with non-linear load |
Efficiency | : | 94.5% | SYSTEM FEATURES |
Transfer Time | : | Utility to Battery: 0ms; Utility to Bypass: 0ms |
Overload | : | Load ≤100%: last 60min; ≤125%: last 10min; ≤150%: last 1min; ≥150% change to bypass |
Short Circuit | : | Hold Whole System | Communication | : | USB, Rs232, Rs485, Parallel port, REPO port, Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional) |
ENVIRONMENTAL | Operating Temperature | : | 0 ~ 40ºC |
Storage Temperature | : | -25 ~ 55ºC (No battery) | Humidity Range | : | 0 ~ 95% (Non-condesing) |
Altitude | : | <1500m, When >1500m, lower the rated power for use | Noise Level | : | <58dB |
PHYSICAL UPS Without External Battery (UPS Only) | ||
Dimension D x W x H (mm) | : | 860 x 255 x 860 |
Net Weight | : | 69 | Gross Weight | : | 82 |
STANDARDS | Safety | : | IEC/EN62040-1, IEC/EN60950-1 |
EMC | : | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |