SE 6102 C33
ICA UPS SE-6102C33 Capacity 60.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.
Model | : | UPS SE6102C33 |
Capacity | : | 60.000 VA / 60.000 W | INPUT |
Nominal Voltage | : | 380 / 400 / 415 Vac (3Ph+N+PE) |
Operating Voltage Range | : | 138 ~ 485 Vac |
Operating Frequency Range | : | 40Hz – 70Hz (50/60Hz Auto-Sensing) |
Power Factor | : | ≥0.99 |
Bypass Voltage Range | : | 220Vac Max. voltage: +25% (optional +10%, +15%, +20%) 230Vac Max. voltage: +20% (optional +10%, +15%) 240Vac Max. voltage: +15% (optional +10%) Min. voltage: -45% (optional -20%, -30%) |
Bypass Frequency Range | : | Frequency synchronize tracing range: ±10% |
ECO Range | : | Same as bypass |
Harmonic Distortion (THDi) | : | ≤3% (100% non-linear load) |
BATTERY | ||
Battery Voltage | : | ±240Vdc |
Backup Time | : | 10 minutes at nominal load |
Charge Current(A) (Charger current can be set according to battery capacity installed) | : | Max. current 20A |
Battery Configuration | : | External |
OUTPUT | ||
Output Voltage | : | 380 / 400 / 415 Vac (3Ph+N+PE) |
Power Factor | : | 1.0 |
Voltage Regulation | : | ±1% |
Frequency Line Mode | : | ±1%/ ±2%/ ±4%/ ±5%/ ±10% of the rated frequency (optional) |
Frequency Bat. Mode | : | 50/60 (±0.2)Hz |
Crest Factor | : | 3:1 |
Harmonic Distortion (THD) | : | ≤2% with linear load ≤4% with non-linear load |
Efficiency | : | 95.5% |
SYSTEM FEATURES | ||
Transfer Time | : | Utility to Battery: 0ms; Utility to Bypass: 0ms |
Protection | : | Short circuit, Overload, Over temperature, Battery low, Fan fault alarm. |
Overload | : | Load≤110%: last 60min,≤125%: last 10min, ≤150%: last 1min |
Short Circuit | : | Hold Whole System |
Alarm | : | Overload, Utility abnormal, UPS fault, Battery low, etc. |
Communication | : | USB, RS232, RS485, Parallel port, REPO port, LBS port, dry contact, Intelligent slot, SNMP card (optional), Relay card (optional) |
Backfeed Protection | : | Support |
Remote LCD | : | Support |
ENVIRONMENTAL | ||
Operating Temperature | : | 0 ~ 40ºC |
Storage Temperature | : | -25 ~ 55ºC (No battery) |
Humidity Range | : | 0 ~ 95% (Non-condesing) |
Altitude | : | <1500m, When >1500m, lower the rated power for use |
Noise Level | : | <58dB |
PHYSICAL UPS Without External Battery (UPS Only) | ||
Dimension D x W x H (mm) | : | 828 x 250 x 868 |
Net Weight | : | 83 |
Gross Weight | : | 95 |
STANDARDS | ||
Safety | : | IEC/EN62040-1, IEC/EN60950-1 |
EMC | : | IEC/EN62040-3, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |