CT 382 B

ICA UPS CT382B Capacity 300 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.

Model : UPS CT382B
Capacity : 600 VA / 300 W
AC Input Voltage : 160 – 250 V
AC Input Current : 1.6 A
AC Input Frequency : 50 ± 3% Hz
AC Input Protection : Fuse 3.15 A
DC Input Internal Battery : 1 x 12 V, 7 Ah
DC Input Protection : 30 A
Inverter Output Waveform : SYNTHESIZED SINEWAVE
Inverter Output Voltage : 220 ± 5% V
Inverter Output Frequency : 50 Hz
Inverter Output Efficiency : >80 %
Charger Type : CONSTANT VOLTAGE
Charger Voltage : 13.5 V
Charger Current : 1.5 A
Transfer Time : ≤4 ms
Back Up Time : 10 min
Indicator : LED & BUZZER
Operation Temperature : 0 – 40 °C
Dimension(DxWxH) : 340 x 95 x 145 mm
Weight Netto : 6 Kg
Weight Gross : 7 Kg