RN 1102 C11
ICA UPS RN 1102 C11 Capacity 10.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.
Type | : | UPS RN1102C11 |
Capacity | : | 10.000 VA / 9000 W |
INPUT | ||
Input mode | : | Single phase + Ground |
Power factor | : | ≥0.99 |
Rating voltage | : | 220 / 230 / 240 Vac (can be set) |
Rating frequency | : | 50 / 60Hz (auto sensing) |
Voltage range | : | 120 ~ 276 Vac |
Frequency range | : | 45 ~ 55Hz / 54 ~ 66Hz |
Bypass voltage range | : | 220Vac max : 10%, 15%, 20% or 25%, default : 25% ; 230Vac max : 10%, 15% or 20%, default +20% ;240Vac max : +10% or 15%, default +15% Min : 20%, 30% or 45%, default 45% |
Bypass frequency range | : | ±1%, ±2%, ±4%, ±5%, ±10% |
THDI | : | ≤3% (100% liner load, input THDV ≤1%) ; ≤5% (100% liner load, input THDV ≤1%) |
BATTERY | ||
Battery number | : | 16 / 18 / 20 pcs (can be set) |
Battery type | : | VRLA |
Charge model | : | Boost charge or float charge auto switch |
Charge time | : | Boost charge up to 20Hr (Max) |
Charge current (A) | : | 1A (S) / 10A (H) |
OUTPUT | ||
Output Type | : | Single phase + Ground |
Ouput precision | : | 1.0% |
Voltage distortion (THD) | : | ≤2% at 100% liner load; ≤5% at 100% non-liner load |
Rating voltage | : | 220 / 230 / 240V |
Frequency precision | : | ±0.1% |
Rating frequency | : | 50 / 60Hz |
Frequency track speed | : | 1 Hz/s |
Overload | : | 105% ~ 110%, 1 Hr; 110% ~ 125%, 10min; 125% ~ 150%, 1min; ≥150% 200ms |
Peak Value factor | : | 3 : 1 |
Efficiency at normal | : | ≥90% |
Dynamic respond | : | 5.0%; 20ms |
DC heft | : | ≤500mV |
SWITCH | ||
Between normal mode and battery mode | : | 0ms |
Between Inverter mode and Bypass | : | 0ms ; Unlock : <15ms (50Hz), <13.33ms (60Hz) |
Norse | : | <55dB (1m) |
Display | : | LCD + LED |
Safety | : | Metting IEC62040-1 GB4943 |
Max input voltage | : | 320Vac, 1 Hr |
EMI | : | Conduction : IEC 62040-2; Radiation : IEC 62040-2; Harmonics : IEC 62040-2 |
EMS | : | IEC 62040-2 |
MTBF | : | 250.000Hr 1 + 1 400.000Hr |
MTTR | : | 30min |
Isolation resistance | : | >2M Ω (500Vdc) |
Isolation intension | : | 2820Vdc, <3.5mA, 1 min |
Surge | : | Meeting IEC60664-1 1.2/50uS + 8/20uS 6Kv/3kA |
Protection | : | Ip20 |
Parallel circuimfluence | : | 1 + 1 ≤ 8%, N + 1 ≤ 3% |
Parallel equal current | : | 1 + 1 ≤ 8%, N + 1 ≤ 10% |
Dimension (DxWxH) | : | 790 x 580 x 290 mm |
Weight | : | 30 Kg |