ICA UPS RN 1102 C33 Capacity 10.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.

Model : UPS RN1102C33
Capacity : 10000 VA / 10000 W
INPUT  
Nominal Voltage : 380 / 400 / 415 Vac (3Ph+N+PE)
Operating Voltage Range : 138 ~ 485 Vac, 305 ~ 485 Vac no derating, 138 ~ 485 Vac derate to 40% load
Operating Frequency Range : 40Hz ~ 70Hz
Power Factor : ≥0.99
Harmonic Distortion (THD) : ≤3% (100% non-linear load)
Bypass Voltage Range : 220Vac Max. voltage: +25% (optional +10%, +15%, +20%)
230Vac Max. voltage: +20% (optional +10%, +15%)
240Vac Max. voltage: +15% (optional +10%)
Min. voltage: -45% (optional -10%, -15%, -20%, -30%)
Frequency synchronize tracing range: ±10%
Generator input : Support
OUTPUT    
Output Voltage : 380 / 400 / 415 Vac (3Ph+N+PE)
Voltage Regulation : ±1%
Power Factor : 1.0
Frequency Line Mode :

Synchronize with input;
When input frequency >±10% (±1% / ±2% / ±4% / ±5% optional)

Frequency Bat. Mode : 50/60* (1±0.02%)Hz
Crest Factor : 3:1
Harmonic Distortion (THD) : ≤2% with linear load
≤4% with non-linear load
Efficiency : 95.5%
BATTERY    
Battery Voltage : Optional Voltage:
±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc
(30/32/34/36/38/40/42/44/46/48/50 pcs optional)
360 Vdc ~ 600 Vdc (30 ~ 50 pcs, 30 pcs define, 36 ~ 50 pcs no power derating);
32 ~ 34 pcs output power factor 0.9; 30 pcs output power factor 0.8)
Charge Current (A) (Charger current can be set according to battery capacity installed : Max. current 18A
SYSTEM FEATURES    
Transfer Time : Utility to Battery: 0ms; Utility to Bypass: 0ms
Overload : Load ≤110%: last 60min, ≤125%: last 10min, ≤150%: last 1min
Alarm : Overload, Utility abnormal, UPS fault, Battery low, etc
Backfeed protection : Support
Protection : Short circuit, Overload, Over temperature, Battery low, Fan fault alarm
Communication : USB, RS232, RS485, Parallel port, Dry contact port, REPO port, Backfeed port, Intelligent slot, SNMP card (optional)
ENVIRONMENTAL    
Operating Temperature : 0 ~ 40ºC
Storage Temperature : -25 ~ 55ºC (No battery)
Humidity Range : 0 ~ 95% (Non-condesing)
Altitude : <1500m, When >1500m, lower the rated power for use
Noise Level : <55dB
PHYSICAL UPS Without External Battery (UPS Only)    
Dimension D x W x H (mm) : 790 x 482 x 130 (3U)
Net Weight : 25
STANDARDS    
Safety : IEC/EN62040-1, IEC/EN60950-1
EMC :

IEC/EN62040-3, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8