RN 1100 C
ICA UPS RN 1100 C Capacity 1000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.
Type | : | UPS RN1100C |
Capacity | : | 1000 VA / 900 W |
INPUT | ||
Rated voltage | : | 200 / 208 / 220 / 230 / 240Vac |
Voltage range | : | 110 ~ 300Vac (depend on load percentage) |
Frequency range | : | 40 ~ 70Hz (auto detect) |
Power factor | : | ≥0.99 |
Bypass voltage range | : | Bypass high voltage point Setting in LCD from 230Vac to 264Vac (Default: 264Vac) Bypass low voltage point Setting in LCD from 170Vac to 220Vac (Default: 170Vac) |
Generator input | : | Support |
BATTERY | ||
Battery voltage | : | 24Vdc |
Typical recharge time | : | 4 hours (to 90% of full capacity) |
Backup time | : | Estimated remaining time displayed on the LCD |
Charging current (max.) | : | 1A |
OUTPUT | ||
Output voltage | : | 200 / 208 / 220 / 230 / 240Vac |
Power factor | : | 0.9 |
Voltage regulation | : | ±1% |
Frequency line mode | : | 45 ~ 55Hz (for 50Hz) or 55 ~ 65Hz (for 60Hz) |
Frequency bat. mode | : | 50 / 60 (±0.01%)Hz |
Crest factor | : | 3 : 1 |
Harmonic distortion (THDv) | : | ≤3% with linear load; ≤6% with non-linear load |
Waveform | : | Pure sinewave |
Efficiency (AC mode full load) | : | >88% |
SYSTEM | ||
Transfer time | : | Utility to Battery: 0ms; Utility to Bypass: <4ms |
Overload (Line Mode) | : | Load ≤110%: last 10min; ≤130%: last 1min; ≤150%: last 5S; >150% turn to bypass mode (1 ~ 3kvA) Load ≤110%: last 60min; ≤125%: last 10min; ≤150%: last 1S; >150% turn to bypass mode (6 ~ 10kvA) |
Short circuit | : | Hold whole system |
Overheat | : | Line mode: Switch to Bypass; Backup Mode: Shutdown UPS immediately |
Battery low | : | Alarm and switch off |
EPO (optional) | : | Shutdown UPS immediately |
Audible & visual alarm | : | Line failure; Battery Low, Overload, System Fault |
Coomunication interface | : | USB (or RS232), SNMP card / relay card (optional) |
ENVIRONMENTAL | ||
Operating temperature | : | 0 ~ 40º C |
Storage temperature | : | -25 ~ 55ºC |
Humidity range | : | 20 ~ 90% (non-condensing) |
Altitude | : | <1500m |
Noise level | : | <50dB at 1 meter |
PHYSICAL | ||
Dimension W x H x D (mm) | : | 440 x 86.5 x 325 (2U) |
Net weight (kg) | : | 11.5 Kg |
Gross weight (kg) | : | 13.9 Kg |
STANDARDS | ||
Safety | : | IEC/EN62040-1, IEC/EN60950-1 |
EMC | : | IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 |
BATTERY PACK for 6~10kVA | ||
Voltage | : | +/-120Vdc |
Type & number | : | 20 x 12V/7Ah SLA Battery |
Dimensions W x H x D (mm) | : | 440 x 130 x 720 (3U) |
Net weight (kg) | : | 57 Kg |
Gross weight (kg) | : | 62 Kg |