SIN 10 KEP
ICA UPS SIN 10 KEP Capacity 10.000 VA, inverter only works when the AC input voltage is low or loss. When the AC input voltage is in normal condition, ICA UPS will stabilize and filter the AC input voltage and supply a clean and stable AC voltage to the ICA UPS output and charge the battery. When the AC input voltage is low or loss, inverter will replace it and supply a stable AC voltage within a very short transfer time.
Model | : | UPS SIN10KEP |
Capacity | : | 10000 VA |
Power Rating | : | 9000 W |
INPUT | ||
Operating voltage range | : | 380/400/415Vac (380-25%, 415+20%), (3Ph+N+PE) |
Operating frequency range | : | 50 / 60Hz ± 5Hz |
Power factor | : | >0.97 (with filter) |
Rated current | : | 15 A |
OUTPUT | ||
Output voltage | : | 380/400/415Vac (±1%) |
Output frequency | : | 50 / 60Hz (±0.05%) |
Frequency regulation (battery mode) | : | 50 / 60Hz ± 0.05% |
Output waveform | : | Sine wave |
Power factor | : | 0.9 (lagging) |
Harmonic distortion (THD) | : | <3% (linear load) |
Overload capacity | : | When 110% / 125% / 150% overload, maintain 60min/ 10min/ 1min |
Crest factor | : | 3 : 1 (max) |
Efficiency | : | >89% |
BYPASS | ||
Rated voltage | : | 380/400/415Vac |
Bypass voltage range | : | Upper limit: +10%, +15%, +20% can be set ; LOwer limit: -10%, -20%, -30%, -40% can be set |
Rated frequency | : | 50 / 60Hz |
Bypass frequency range | : | ±2% (±10%, ±20% can be set) |
Transfer time to bypass | : | 0 ms / 1 ms |
Overload capacity | : | 15 times the rated current (10ms), 5 times the rated current (5s) |
BATTERY | ||
Battery voltage | : | 384 Vdc |
Backup time (min) External battery | : | 6 ~ 10 |
SYSTEM FEATURES | ||
Transfer time | : | 0ms (Line mode – Battery mode) |
Overload | : | 110% / 60min, 125% / 10min, 150% / 1min |
Communication interface | : | LCD display, LED indication, Dry contact, RS232, RS485, SNMP card (optional) |
Optional | : | Harmonic filter, SNMP adapter, LBS cables, battery temperature sensor, Bypass current sharing inductor |
PANEL DISPLAY | ||
LED | : | Indicate the status of input, inverter, bypass, battery, output |
LCD | : | Display input/output voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, set parameters |
ENVIRONMENTAL | ||
Operating temperature | : | 0 ~ 40ºC |
Storage temperature | : | -25ºC ~ 55ºC |
HUmidity range | : | 0 ~ 95% (non-condensing) |
Altitude | : | <1500m |
Noise level | : | <60 dB |
PHYSICAL | ||
Weight Netto | : | 217 Kg |
Weight Gross | : | 272 Kg |
Dimension (WxDxH) | : | 570 x 800 x 1195 mm |
STANDARDS | ||
Safety | : | IEC/EN62040-1 IEC/EN60950-1 |
EMC | : | IEC/EN62040-2; IEC61000-4-2; IEC61000-4-3; IEC601000-4-4; IEC61000-4-5; IEC61000-4-6; IEC61000-4-8 |